Announcements
Clinical and Experimental Obstetrics & Gynecology (CEOG) is published by IMR Press from Volume 47 Issue 1 (2020). Previous articles were published by another publisher on a subscription basis, and they are hosted by IMR Press on imrpress.com as a courtesy and upon agreement with S.O.G.
Original Research
Evaluation of fetal weight by the study of two biometric parameters obtained echographically
Show Less
1
Department of Obstetrics and Gynecology, University of Siena
2
Institute of Phisics, University of Siena
3
Chair of Obstetric and Gyneco1ogical Pathology, University of Chieti
Clin. Exp. Obstet. Gynecol. 1979, 6(4), 280–285;
Published: 10 December 1979
Abstract
The AA. have specified by analytic method, a mathematical formula which allows to eva-luate the fetal weight in uterus, by the echo-graphic measurement of two parameters. The operative control carried out on 39 pregnant women at term, within 10 days after delivery, has given a probable error of about 100 g/kg of fetal body mass. The formula suggested, when compared with those of other AA., has the advantage of a simple execution and an acceptable precision of results.