IMR Press / CEOG / Volume 47 / Issue 4 / DOI: 10.31083/j.ceog.2020.04.5422
Open Access Review
Current methods of non-invasive fetal heart rate surveillance
Show Less
1 School of Health Sciences, Midwifery Department, International Hellenic University, Thessaloniki, Greece
2 Third Department of Obstetrics and Gynecology, Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
*Correspondence: anattheo@midw.teithe.gr; anattheo@ihu.gr (ANATOLI THEODORIDOU)
Clin. Exp. Obstet. Gynecol. 2020, 47(4), 459–464; https://doi.org/10.31083/j.ceog.2020.04.5422
Submitted: 9 November 2019 | Accepted: 10 February 2020 | Published: 15 August 2020
Copyright: © 2020 Theodoridou et al. Published by IMR press.
This is an open access article under the CC BY 4.0 license https://creativecommons.org/licenses/by-nc/4.0/.
Abstract

Introduction: As accurate fetal evaluation during labor is essential, there is a continuous need for better noninvasive ways of monitoring. Electronic fetal monitoring (EFM) is an essential tool towards effective fetal assessment during labor, with the invasive Intrapartum ST Segment Analyses (STAN) system an early favorite. There are very few non-invasive EFM devices worldwide, with only two having Food and Drug Administration (FDA) approval. Methodology: This state of the science review focuses on the most recent available scientific data regarding the role of non-invasive EFM and its effect on perinatal outcomes. Results: The Monica AN24 system, FDA approved and comparable to an external Doppler CTG, is independent of maternal BMI. The Mind child Meridian monitor, the second EFM device with FDA approval, is comparable to STAN, but with up to 32 electrodes for improved accuracy it can be difficult for medical professionals to master. The Nemo System, new to the market, was found to be highly acceptable as a 24-hour monitoring device by pregnant women in a single inaugural pilot study. Discussion: Non-invasive monitoring technology is making progress but there are still issues with signal acquisition and quality that stem from the newfound mobility of the monitored pregnant women. The two FDA approved devices are promising with a few caveats and there are also new devices that aim to improve on the shortcomings of the leaders with promising advances in signal acquisition and processing via additional electrodes and setups.

Keywords
Electrocardiography
Electrocardiotocography
Peripartum care
Cardiotocography
Introduction

The evaluation of fetal well-being during labor has been a significant consideration in obstetrics throughout the years. Therefore, considerable effort has been made towards developing evaluation methods that are both non-invasive and reliable and could help reduce perinatal morbidity and mortality [1]. A circadian interdependency between Maternal Heart Rate (MHR) and Fetal Heart Rate (FHR) [2], signal interference from the movement of both the fetus and the mother, further maternal noise from uterine contractions, respiration, abdominal muscle artifacts, as well as electrical noise from the device and power line are just some of the problems that these new devices are called to face [3]. The past few years have seen significant improvements in the accuracy of FHR monitoring, utilizing advanced signal processing techniques. There are numerous methods available with different clinical efficacy, due to variations in sensitivity, specificity, negative, and positive predictive value [4, 5] and not without their share of controversy [6-8].

Electronic fetal monitoring (EFM) by means of cardiotocography, electrocardiography, and other methods is an essential tool towards effective fetal assessment during labor [9, 10].

This state of the science review focuses on the most recent available scientific data regarding the role of non-invasive electrocardiographic monitoring and its effect on perinatal outcomes.

Early Research on Electronic Fetal Heart Rate Monitoring

Most of the monitoring techniques currently used in obstetric practice have been developed during the 20th century and have led to a significant reduction in perinatal mortality. The 1950s saw the development of phonocardiography by Hon [11], which quickly moved in the early 60s to cardiotocography (CTG), a non- invasive electronic monitoring system that allows the continuous recording of FHR by using Doppler Effect technology [12]. Uterine activity is simultaneously monitored by the use of a tocodynamometer, applied either intrauterine or, on the maternal abdomen. Its stated purpose was to reduce the incidence of fetal hypoxia [13]. It is a well-used method but not without serious shortcomings [1, 13-15]. The lack of real-time beat to beat data, frequent repositioning of the transducers causing up to 40% signal loss, the inability to always discriminate between MHR and FHR, and an array of well-documented artefacts have stigmatized this method [1, 13-15]. Also, it is not easily implemented even when upgraded with wireless parts, as it restricts mobility much more so than newer technologies [14, 16].

Initially, numerous studies were published showing that screening all pregnant women, both before and during labor with CTG, could contribute significantly to the reduction of perinatal morbidity and mortality. However, during the 1980s, a higher incidence of operative delivery and postnatal depression, negatively affecting breastfeeding and infant care, was reported with the use of this method [17, 18].

Fetal Electrocardiography

Magnetocardiography and non-invasive fetal electrocardiography are the other two current methods in use for EFM. Magnetocardiography [19] requires amagnetically shielded environment and high-end equipment. The restricted availability of this technology, as well as the lack of mobility for the patient [20], outweigh the benefits of this approach [21].

Fetal electrocardiography on the other hand allows for the interpretation of the electrical activity of the fetal heart and provides information regarding the physiological state of the fetus that can help clinicians to make appropriate and timely decisions during labor. The fetal cardiac electrical activity during each beat can besubdivided into P, QRS, and T waves. Each wave corresponds to a different phase in the cardiac cycle: P waves correspond to atrial contraction, QRS to ventricular contraction, and T waves to ventricular repolarization [22, 23]. Repolarization of myocardial cells is very sensitive to metabolic dysfunction and may be reflected in changes in the ST waveform. Thus, in adults with myocardial infarction, the ST segment, the period that follows the QR complex and leads to the T wave, may be elevated [18, 23]. Similar findings can be observed in fetuses under conditions of moderate to severe hypoxemia [4, 24, 25]. This can be measured only after the membranes have ruptured and cervical dilation has exceeded 2-3 cm [14, 18]. Fetal electrocardiography is not as widely used in clinical practice as cardiotocography since many obstetricians are not familiar with the technology and consider it mostly an experimental technique [6, 8, 26]. One such method is the ST analysis (STAN) system, STAN monitor (Neoventa Medical, Mölndal, Sweden), an invasive technique most commonly used in Sweden, which measures ST segment deviation and T/R amplitude ratio by applying a scalp electrode to the fetal head during labor in high-risk pregnancies [27]. STAN was introduced to daily practice in 2000. Its use has shown promise in reducing neonatal metabolic acidosis, but not in reducing neonatal morbidity, thus it has not been widely adopted as a standard method outside of Sweden [4, 18, 28-31].

To date, six randomized controlled trials utilizing STAN have been performed, five of which have published their results [32-37]. Furthermore, several related meta-analyses have been released. The meta-analyses showed that combined cardiotocography with STAN as compared to no monitoring reduces the risks of vaginal operative delivery by about 10% and of fetal blood sampling by 40% [38, 39].

An early meta-analysis of five randomized controlled trials, which included 15,352 parturients, compared the combination of fetal electrocardiography with ST waveform analysis and CTGversus conventional CTG. The addition of STAN led to a non-significant reduction in metabolic acidosis (RR 0.72) but a significant decrease in fetal blood sampling (RR 0.59) and total operative deliveries (RR 0.94) [40]. A later systematic review [4] concluded that the use of an internal procedure to place an electrode on the fetal scalp is a serious risk for the fetus that cannot be negated by the modest, at best, results in reducing operational births.

A recent meta-analysis [18] of six RTCs was conclusive; STAN does not have a place in modern obstetrics since its only benefit is the reduction of metabolic acidosis but not operative deliveries, concluding that the benefits were insufficient to justify using ST waveform analysis as an intrapartum monitoring method.

Non-invasive Fetal Electrocardiography

Non-invasive fetal electrocardiography devices are limited in number as there are only three available worldwide, with only two having US Food and Drug Administration (FDA) approval. The available devices include the Monica AN24 monitor (Monica Healthcare, Nottingham, UK), the MERIDIAN monitor from MindChild Medical (North Andover, MA), and the recently introduced Nemo Fetal Monitoring System (Parides/Atlantis System, Nemo Healthcare, Veldhoven, The Netherlands) [41]. There is recent activity with small start-ups filing patents on non-invasive fetal ECG technology, but only the patent information is readily available. One of them, a yet unnamed device, is currently in trials from KhAI-MEDICA, Kharkіv, in Ukraine [42].

MindChild MERIDIAN Monitor

The MindChild MERIDIAN Monitor [23] is frequently used in preclinical signal processing related research to improve the related algorithms and has been cited as an example that non-invasive fetal electrocardiography devices are the way forward. The Meridian monitor was found comparable to STAN [43]. One benefit of this technique is that the Meridian monitor’s abdominal electrodes can be applied without any prior skin preparation [43]. Researchers also are using the MindChild Medical monitor to evaluate fetal ECG waveform patterns that predict in-utero inflammation. Although the 32 abdominal electrodes allow for higher accuracy, the Meridian monitor can be very inconvenient both for the medical staff that have to ensure proper adhesion of up to 32 electrodes and also for the patient that has to endure monitoring for hours [42].

Nemo Fetal Monitoring System

The Nemo System (Parides/Atlantis System, Nemo Healthcare, Veldhoven, The Netherlands) is very new to the market and so far has an inaugural pilot study evaluating the acceptance and comfort of the system by pregnant women. The case-control cohort study for acceptance and potential use as a clinical device for fetal monitoring took place at the out-patient clinic of University Hospital Heidelberg, Department of Gynecology and Obstetrics, Germany in 2017 and demonstrated a high level of patient acceptance [41]. It requires a minor skin preparation with water soap and medical abrasive paper to lower skin impedance [41]. Nemo has been used in a study that showed that electrohysterogram (EHG) monitoring is a reliable and reasonable alternative to tocodynamometry and intra-uterine pressure catheters. The study, using Nemo for EHG, showed higher sensitivity for contraction detection and had a better performance than external tocodynamometry during the first stage of labor, regardless of the BMI of the women in labor [44].

Monica AN24

The Monica AN24 (Novii Wireless Patch System, Nottingham, UK) is a non-invasive device using five electrodes placed on the woman’s abdomen, that has been approved by the FDA for monitoring fetal well-being. This device extracts the fetal and maternal electrocardiogram (ECG) and electrohysterogram (EHG) [27].

It has been shown to assess FHR using abdominal surface electrodes accurately. Monika AN24 can be used in a home monitoring setting [45, 46] for continuous telemetric trans-abdominal fetal ECGmonitoring. The electrophysiological signals from the abdominal wall are used to measureFHR,MHR, and uterine contraction data [47, 48]. The device continuously monitors MHR which reduces the MHR/FHR ambiguity when compared with cardiotocography [48, 49]. In addition, the Monica AN24TM can accurately record the FHR from as early as 20 weeks’ gestation [50]. It has been utilized in measuring MHR, FHR and uterine activity to help associate several distinct MHR patterns (such as periodic changes, variability, tachycardia, bradycardia) with uterine activity [49, 51] as well as fetal growth and birth weight [52].

Unlike the STAN system, the Monica AN24 can also be used during pregnancy, and not only intrapartum [53]. The Monica system is comparable to the signal quality of the external Doppler CTG independent of maternal BMI [53-55], and fetal presentation during delivery does not influence fetal signal success using the Monica AN24 system [55].

A recent study suggests a potential role for Monica AN24 in the monitoring of fetal arrhythmias as it provided high-quality tracings in 9 of 11 fetuses with gestational age < 26 or > 34 weeks [56]. Furthermore, it could be a useful tool to detect precise fetal cardiac time intervals (fCTIs) from 32 weeks’ gestational age onwards as a very recent study indicated [57].

The success rate of beat to beat recording is an issue with Monica AN24. Long-term Monica AN24 recordings have FHR signal dropouts due to movement of the woman, a clear limitation of abdominal fECG recording. Huhn et al. found differences in home and hospital-bound cases with better quality recordings in the home-based group during nighttime as opposed to daytime. They concluded that the success of beat-to-beat FHR detection depended strongly on whether the monitoring was done at home or at the hospital and was also dependent on the time of recording, maternal activity levels, and maternal posture. Thus they concluded that Monica AN24 might have limited clinical utility especially if it is an unsupervised recording with physical activity or posture shifts [58]. A very recent study from Hayes-Gill et al., in 2020 [59], funded by Monica Healthcare Ltd, has assessedAN24’s accuracy against ultrasound and abdominal electrocardiogram and found it conforms better with patterns derived using a direct fetal electrode [59]. They concluded that the AN24 is good enough to aid in the clinical interpretation of FHR patterns. Table 1 summarizes all current devices and their pros and cons.

Table 1Pros and Cons of current fetal heart rate surveillance devices.
Method Main device Type Pros Cons
Cardiotocography DopplerUltrasound/toco dynamometer I Most commonly used, Contraction monitoring, HR time series, Reduces incidence of fetal hypoxia [13] Expert user required, No real-time beat to beat data, Signal loss, (MHR)/(FHR) discrimination issues [1, 13-15]. Restricts mobility [14, 16]. Higher incidence of operative delivery [17, 18]
Magnetocardiography [19] Superconducting QuantumInterferenceDevice (SQUID) sensors NI. Multichannel, Good SNR for fetal signals, Good results [20] Expert user required. Specialist set up required. Short term monitoring only. Expensive, lack of mobility [21]
Electrodeelectrocardiography STAN monitor [27] I Very good FHR, Reduces neonatal metabolic acidosis, [4, 18, 28-31]. Reduces the need for blood sampling [40] Expert user required. Use only after the membranes have ruptured and cervical dilation has exceeded 2-3 cm [14, 18]Latest meta-analysis has concluded that STAN does not have a place in modern obstetrics [4, 18]
MERIDIANMonitor* [23] NI FDA approved for Weeks of Gestation (WOG) ≥ 36, Comparable to STAN [43] No skin preparation, Number of electrodes[32] can be inconvenient for both staff and patient [42]
NEMO System [41] NI Highly accepted by patients [41]. Minor skin preparation, New to the market, 2 studies only [41, 44]
Non-invasive fetal electrocardiography FDA approved for WOG ≥ 36 weeks, Europe, WOG (≥ 20 weeks), Real-time FH, MHR EHG capable, Equal or even superiority in signal quality to the external Doppler, CTG independent of maternal BMI [54, 55] evaluate precise fetal cardiac time intervals (fCTIs) [57] Skin preparation required, Success of beat-to-beat fHR detection, dependant strongly on location, timing, maternal activity levels, and maternal posture. Might have limited clinical utility if it is unsupervised with physical activity or posture shifts [58].
MONIKAAN24*/Novii NI
KhAI-MEDICA [42] NI Only patent submitted N/A N/A

Abbreviations: I, invasive; NI, Non-invasive.

Concluding Remarks

There has been a drive in the last few years for significant improvements in the accuracy of FHR monitoring, with advanced algorithmic processes and safety, and an investment in non-invasive technologies [4-8, 16, 21, 24, 41, 42, 46, 60] not without their share of controversies. The majority of the obstetrics community has embraced EFM as an essential tool towards effective fetal assessment during labor [9, 10]. Although it is still unclear if continuous intrapartum fetal monitoring does indeed offer an improvement on newborn outcomes such as a reduction in perinatal mortality, the technology does appear to lead to more operative vaginal deliveries and caesarean deliveries [61].

The STAN system uses a fetal scalp electrode and, consequently, can only be used in parturients with cervical dilation of at least 3-4 cm [27]. Furthermore, myometrial contractions are still recorded transabdominal, and the woman is not mobile.

Non-invasive fetal electrocardiography devices are very few with only two having FDA approval so far, Monica AN24 and MERIDIAN Nemo Fetal Monitoring System is the latest commercial addition [41].

As far as non-invasive monitoring is concerned, the technology is making progress as comparedto invasive technologies, but there are still issues with signal acquisition and quality that stem from the newfound mobility of the monitored expecting women. True wireless devices are still in patent [62-64] or prototype stage [65-67], thus are not in any way directly comparable to the devices reviewed. The two FDA approved devices are promising, with a few caveats, and there are also new but unproven devices that target the shortcomings of the industry leaders by promising improvements in signal acquisition and processing via additional electrodes and setups [23, 41].

Focusing on improved algorithms for deciphering as well as improving the signal accusation process seems to be the way to improve the technology and the above-mentioned devices are moving in that direction [59]. An exhaustive review [68] of the current signal processing techniques argues that the way forward is the combination of different computational techniques as well as creating hybrid devices to be able to accurately capture FHR and the rest of the fetal modalities.

In conclusion, non-invasive monitoring devices appear to be trending and are considered almost as reliable, but certainly much safer than established methods. When used by trained personnel and in combination with other peripartum parameters, these devices can lead to improved outcomes but not in the reduction of caesarian births as originally promised. Finally, the main result of the current literature is that new methods of fetal echocardiography and electrohysterography could achieve a reduction in medical intervention and cesarean section, although this does not necessarily translate into reduced perinatal morbidity and fetal wellbeing.

Hopefully the new monitoring devices presented here will become the milestones on the road to the much-needed paradigm shift in FHM.

Acknowledgments

The authors would like to thank the reviewers for their very valuable contribution.

Conflict of Interest

The authors have no conflicts of interest to disclose.

References
[1]
Ayres-de-Campos D., Spong C.Y., Chandraharan E.: “FIGO consensus guidelines on intrapartum fetal monitoring, Cardiotocography”. International Journal of Gynecology & Obstetrics, 2015, 131, 13-24. 10.1016/j.ijgo.2015.06.02026433401https://www.ncbi.nlm.nih.gov/pubmed/26433401
[2]
Sletten J., Kiserud T., Kessler J.: “Effect of uterine contractions on fetal heart rate in pregnancy, a prospective observational study”. Acta obstetricia et gynecologica Scandinavica, 2016, 95, 1129-35. 10.1111/aogs.1294927460848https://www.ncbi.nlm.nih.gov/pubmed/27460848
[3]
Behar J.: “Extraction of clinical information from the non-invasive fetal electrocardiogram”. arXiv preprint arXiv, 2016, 160601093. 32550251https://www.ncbi.nlm.nih.gov/pubmed/32550251
[4]
Neilson J.P.: “Fetal electrocardiogram (ECG) for fetal monitoring during labour”. Cochrane Database of Systematic Reviews, 2015, 12. 10.1002/14651858.CD01350531845767https://www.ncbi.nlm.nih.gov/pubmed/31845767
[5]
Khandoker A.H., Marzbanrad F., Kimura Y.: “Recent advances in doppler signal processing and modelling techniques for fetal monitoring”. Frontiers in Physiology, 2018, 9, 691. 10.3389/fphys.2018.0069129922181https://www.ncbi.nlm.nih.gov/pubmed/29922181
[6]
Clark S.L., Hamilton E.F., Garite T.J., Timmins A., Warrick P.A., Smith S.: “The limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic academia”. American Journal of Obstetrics & Gynecology, 2017, 216, 163, e1-e6. 10.1016/j.ajog.2016.10.009https://linkinghub.elsevier.com/retrieve/pii/S0002937816308729
[7]
Ogunyemi D., Jovanovski A., Friedman P., Sweatman B., Madan I.: “Temporal and quantitative associations of electronic fetal heart rate monitoring patterns and neonatal outcomes”. The Journal of Maternal-Fetal & Neonatal Medicine, 2018, 1-10. 10.1097/00005792-198401000-000016690883https://www.ncbi.nlm.nih.gov/pubmed/6690883
[8]
Eden R.D., Evans M.I., Britt D.W., Evans S.M., Schifrin B.S.: “Safely lowering the emergency Cesarean and operative vaginal delivery rates using the Fetal Reserve Index”. The Journal of Maternal-Fetal & Neonatal Medicine, 2018, 1-7. 10.1097/00005792-198401000-000016690883https://www.ncbi.nlm.nih.gov/pubmed/6690883
[9]
Yli B., Kjellmer I.: “Pathophysiology of foetal oxygenation and cell damage during labour”. Best Practice & Research Clinical Obstetrics & Gynaecology, 2016, 30, 9-21. 10.1016/j.bpobgyn.2015.05.00426211833https://www.ncbi.nlm.nih.gov/pubmed/26211833
[10]
Alfirevic Z., Devane D., Gyte G.M., Cuthbert A.: “Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour”. The Cochrane Library. 2017. 10.1002/14651858.CD01027423833567https://www.ncbi.nlm.nih.gov/pubmed/23833567
[11]
Hon E.H.: “The electronic evaluation of the fetal heart rate, Preliminary report”. American Journal of Obstetrics & Gynecology, 1958, 75, 1215-1230. 10.1016/0002-9378(58)90707-513545252https://www.ncbi.nlm.nih.gov/pubmed/13545252
[12]
Schmidt J.V., McCartney P.R.: “History and development of fetal heart assessment, a composite”. Journal of Obstetric, Gynecologic, & Neonatal Nursing, 2000, 29, 295-305.
[13]
Peters C.H., ten Broeke E.D., Andriessen P., Vermeulen B., Berendsen R.C., Wijn P.F., et al.: “Beat-to-beat detection of fetal heart rate, Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain”. Physiological measurement, 2004, 25, 585. 10.1088/0967-3334/25/2/01515132321https://www.ncbi.nlm.nih.gov/pubmed/15132321
[14]
Clifford G.D., Silva I., Behar J., Moody G.B.: “Non-invasive fetal ECG analysis”. Physiological measurement, 2014, 35, 1521. 10.1088/0967-3334/35/8/15212f442ffb-07ac-4a49-91fa-91f935c70186http://dx.doi.org/10.1088/0967-3334/35/8/1521
[15]
Bakker P., Colenbrander G., Verstraeten A., Van Geijn H.: “The quality of intrapartum fetal heart rate monitoring”. European Journal of Obstetrics & Gynecology and Reproductive Biology. 2004, 116, 22-27.
[16]
Nguyen K., Bamgbose E., Cox B.P., Huang S.P., Mierzwa A., Hutchins S., et al.: “Wearable fetal monitoring solution for improved mobility during labor & delivery”. 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2018, IEEE.
[17]
Rzepka R., Torbé A., Kwiatkowski S., Blogowski W., Czajka R.: “Clinical outcomes of high-risk labours monitored using fetal electrocardiography”. Annals Academy of Medicine Singapore, 2010, 39, 27.
[18]
Blix E., Brurberg K.G., Reierth E., Reinar L.M., Øian P. S.T.: “waveform analysis versus cardiotocography alone for intrapartum fetal monitoring, a systematic review and meta- analysis of randomized trials”. Acta obstetricia et gynecologica Scandinavica, 2016, 95, 16-27. 10.1111/aogs.1282826610052https://www.ncbi.nlm.nih.gov/pubmed/26610052
[19]
Cuneo B.F., Strasburger J.F., Yu S., Horigome H., Hosono T., Kandori A., et al.: “In utero diagnosis of long qt syndrome by magnetocardiography clinical perspective”. Circulation, 2013, 128, 2183-2191. 10.1161/CIRCULATIONAHA.113.004840be33577f-8447-45d9-96f5-b653317adb8ehttp://dx.doi.org/10.1161/CIRCULATIONAHA.113.004840
[20]
Donofrio M.T., Moon-Grady A.J., Hornberger L.K., Copel J.A., Sklansky M.S., Abuhamad A., et al.: “Diagnosis and treatment of fetal cardiac disease, a scientific statement from the American Heart Association”. Circulation, 2014, 129, 2183-242. 10.1161/01.cir.0000437597.44550.5d70a91e9f-28a6-460b-915b-703b0740f13dhttp://dx.doi.org/10.1161/01.cir.0000437597.44550.5d
[21]
Lakhno I., Behar J.A., Oster J., Shulgin V., Ostras O., Andreotti F.: “The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block”. Maternal health, neonatology and perinatology, 2017, 3, 14.
[22]
Amer-Wahlin I., Kwee A.: “Combined cardiotocographic and ST event analysis, a review”. Best Practice & Research Clinical Obstetrics & Gynaecology, 2016, 30, 48-61. 10.1016/j.bpobgyn.2015.05.00726206514https://www.ncbi.nlm.nih.gov/pubmed/26206514
[23]
Behar J., Zhu T., Oster J., Niksch A., Mah D.Y., Chun T., et al.: “Evaluation of the fetal QT interval using non-invasive fetal ECG technology”. Physiological measurement, 2016, 37, 1392. 10.1088/0967-3334/37/9/139227480078https://www.ncbi.nlm.nih.gov/pubmed/27480078
[24]
Burton G.J., Jauniaux E.: “Pathophysiology of placental-derived fetal growth restriction”. American Journal of Obstetrics & Gynecology, 2018, 218, S745-S61. 10.1016/j.ajog.2017.11.57729422210https://www.ncbi.nlm.nih.gov/pubmed/29422210
[25]
Bhogal K., Reinhard J.: “Maternal and fetal heart rate confusion during labour”. British Journal of Midwifery, 2010, 18, 424-428. 10.12968/bjom.2010.18.7.48781http://www.magonlinelibrary.com/doi/10.12968/bjom.2010.18.7.48781
[26]
Behar J., Andreotti F., Zaunseder S., Oster J., Clifford G.D.: “A practical guide to non-invasive foetal electrocardiogram extraction and analysis”. Physiological measurement, 2016, 37, R1. 10.1088/0967-3334/37/5/R127067431https://www.ncbi.nlm.nih.gov/pubmed/27067431
[27]
Hayes-Gill B., Hassan S., Mirza F.G., Ommani S., Himsworth J., Solomon M., et al.: “Accuracy and reliability of uterine contraction identification using abdominal surface electrodes”. Clinical Medicine Insights, Women's Health, 2012, 5, CMWH. S10444. 10.2217/whe.09.1919392617https://www.ncbi.nlm.nih.gov/pubmed/19392617
[28]
28. Westerhuis M.E., Moons K.G., van Beek E., Bijvoet S.M., Drogtrop A.P., van Geijn H.P., et al.: “A randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST- analysis of the fetal electrocardiogram (STAN®) for intrapartum monitoring”. BMC Pregnancy & Childbirth, 2007, 7, 13. 10.1186/1471-2393-7-1317655764https://www.ncbi.nlm.nih.gov/pubmed/17655764
[29]
Saccone G., Schuit E., Amer-Wåhlin I., Xodo S., Berghella V.: “Electrocardiogram ST analysis during labor, a systematic review and meta-analysis of randomized controlled trials”. Obstetrics & Gynecology, 2016, 127, 127-135. 10.1097/AOG.000000000000119826646135https://www.ncbi.nlm.nih.gov/pubmed/26646135
[30]
Olofsson P., Ayres-de-Campos D., Kessler J., Tendal B., Yli B.M., Devoe L.: “A critical appraisal of the evidence for using cardiotocography plus ECG ST interval analysis for fetal surveillance in labor. Part II, the meta-analyses”. Acta obstetricia et gynecologica Scandinavica, 2014, 93, 571-586. 10.1111/aogs.124124d657ab5-0b67-4ffe-b4f1-b4bd27f40cc9http://onlinelibrary.wiley.com/doi/10.1111/aogs.12412/abstract
[31]
Belfort M.A., Saade G.R., Thom E., Blackwell S.C., Reddy U.M., Thorp Jr J.M., et al.: “A randomized trial of intrapartum fetal ECG ST-segment analysis”. New England Journal of Medicine, 2015, 373, 632-641. 10.1056/NEJMoa150060026267623https://www.ncbi.nlm.nih.gov/pubmed/26267623
[32]
Luzietti R., Erkkola R., Hasbargen U., Mattsson L.Å., Thoulon J.M., Rosén K.G.: “European community multi-center trial ‘fetal ECG analysis during labor’, ST plus CTG analysis”. Journal of perinatal medicine, 1999, 27, 431-440. 10.1515/JPM.1999.05810732301https://www.ncbi.nlm.nih.gov/pubmed/10732301
[33]
Amer-Wåhlin I., Bördahl P., Eikeland T., Hellsten C., Noren H., Sörnes T., et al.: “ST analysis of the fetal electrocardiogram during labor, Nordic observational multicenter study”. The Journal of Maternal-Fetal & Neonatal Medicine, 2002, 12, 260-266.
[34]
Luttkus A.K., Norén H., Stupin J.H., Blad S., Arulkumaran S., Erkkola R.., et al.: “Fetal scalp pH and ST analysis of the fetal ECG as an adjunct to CTG. A multi-center, observational study”. Journal of perinatal medicine, 2004, 32, 486-494. 10.1515/JPM.2004.12115576269https://www.ncbi.nlm.nih.gov/pubmed/15576269
[35]
Kwee A., van der Hoorn-van den Beld C., Veerman J., Dekkers A., Visser G.: “STAN® S21 fetal heart monitor for fetal surveillance during labor, an observational study in 637 patients”.. The Journal of Maternal-Fetal & Neonatal Medicine, 2004, 15, 400-407.
[36]
Amer-Wåhlin I., Hellsten C., Norén H., Hagberg H., Herbst A., Kjellmer I., et al.: “Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring, a Swedish randomised controlled trial”. The Lancet, 2001, 358, 534-538. 10.1016/S0140-6736(01)05703-8https://linkinghub.elsevier.com/retrieve/pii/S0140673601057038
[37]
Ojala K., Vääräsmäki M., Mäkikallio K., Valkama M., Tekay A.: “A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography—a randomised controlled study”. BJOG, An International Journal of Obstetrics & Gynaecology, 2006, 113, 419-423.
[38]
Brown R., Wijekoon J.H., Fernando A., Johnstone E.D., Heazell A.E.: “Continuous objective recording of fetal heart rate and fetal movements could reliably identify fetal compromise, which could reduce stillbirth rates by facilitating timely management”. Medical hypotheses, 2014, 83, 410-417. 10.1016/j.mehy.2014.07.00932958d7c-60ba-4f11-98c9-8dbcf4addc0chttp://dx.doi.org/10.1016/j.mehy.2014.07.009
[39]
Rotariu C., Pasarica A., Andruseac G., Costin H., Nemescu D.: “Automatic analysis of the fetal heart rate variability and uterine contractions”. Electrical and Power Engineering (EPE),2014 International Conference and Exposition on, 2014, IEEE.
[40]
Furdea A., Preissl H., Lowery C.L., Eswaran H., Govindan R.B.: “Conduction velocity of the uterine contraction in serial magnetomyogram (MMG) data, Event based simulation and validation”. Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE, 2011, IEEE.
[41]
Schramm K., Lapert F., Nees J., Lempersz C., Oei S.G., Haun M.W., et al.: “Acceptance of a new non- invasive fetal monitoring system and attitude for telemedicine approaches in obstetrics, a case-control study”. Archives of Gynecology & Obstetrics, 2018, 1-9. 10.1007/s00404-010-1521-220505948https://www.ncbi.nlm.nih.gov/pubmed/20505948
[42]
Viunytskyi O., Shulgin V.: “Signal processing techniques for fetal electrocardiogram extraction and analysis”. Electronics and Nanotechnology (ELNANO), 2017 IEEE 37th International Conference on 2017, IEEE.
[43]
Clifford G., Sameni R., Ward J., Robinson J., Wolfberg A.J.: “Clinically accurate fetal ECG parameters acquired from maternal abdominal sensors”. American Journal of Obstetrics & Gynecology, 2011, 205, 47.e1-e5. 10.1016/j.ajog.2011.02.066https://linkinghub.elsevier.com/retrieve/pii/S0002937811002973
[44]
Vlemminx M.W., Thijssen K.M., Bajlekov G.I., Dieleman J.P., Van Der Hout-Van M.B., Jagt D., et al.: “Electrohysterography for uterine monitoring during term labour compared to external tocodynamometry and intra-uterine pressure catheter”. European Journal of Obstetrics & Gynecology and Reproductive Biology, 2017, 215, 197-205.
[45]
Rauf Z., O'Brien E., Stampalija T., Ilioniu F.P, Lavender T., Alfirevic Z.: “Home labour induction with retrievable prostaglandin pessary and continuous telemetric trans-abdominal fetal ECG monitoring”. PLoS One, 2011, 6, e28129. 10.1371/journal.pone.002812922140522https://www.ncbi.nlm.nih.gov/pubmed/22140522
[46]
Kapaya H., Dimelow E.R., Anumba D.: “Women’s experience of wearing a portable fetal- electrocardiogram device to monitor small-for-gestational age fetus in their home environment”. Women's Health, 2018, 14, 1745506518785620. 10.1177/136345930935859620427636https://www.ncbi.nlm.nih.gov/pubmed/20427636
[47]
Vasak B., Graatsma E.M., Hekman-Drost E., Eijkemans M.J., van Leeuwen J.H.S., Visser G.H., et al.: “Uterine electromyography for identification of first-stage labor arrest in term nulliparous women with spontaneous onset of labor”. American Journal of Obstetrics & Gynecology, 2013, 209, 232, e1-e8. 10.1016/j.ajog.2013.05.056https://linkinghub.elsevier.com/retrieve/pii/S0002937813005450
[48]
Reinhard J., Hayes-Gill B.R., Schiermeier S., Hatzmann H., Heinrich T.M., Louwen F.: “Intrapartum heart rate ambiguity, a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram”. Gynecologic & Obstetric Investigation, 2013, 75, 101-108. 10.1159/00034505923328351https://www.ncbi.nlm.nih.gov/pubmed/23328351
[49]
Odendaal H., Groenewald C., Myers M.M., Fifer W.P.: “Maternal heart rate patterns under resting conditions in late pregnancy”. Trends in research, 2018, 1. 10.15761/TR.100012030775690https://www.ncbi.nlm.nih.gov/pubmed/30775690
[50]
Hofmeyr F., Groenewald C., Nel D., Myers M., Fifer W., Signore C., et al.: “Fetal heart rate patterns at 20 to 24 weeks gestation as recorded by fetal electrocardiography”. The Journal of Maternal-Fetal & Neonatal Medicine, 2014, 27, 714-718.
[51]
Ibrahim S., Jarefors E., Nel D.G., Vollmer L., Groenewald C.A., Odendaal H.J.: “Effect of maternal position and uterine activity on periodic maternal heart rate changes before elective cesarean section at term”. Acta obstetricia et gynecologica Scandinavica, 2015, 94, 1359-1366. 10.1111/aogs.1276326335140https://www.ncbi.nlm.nih.gov/pubmed/26335140
[52]
Odendaal H., Kieser E., Nel D., Brink L., du Plessis C., Groenewald C., et al.: “Effects of low maternal heart rate on fetal growth and birthweight”. International Journal of Gynecology & Obstetrics, 2019, 146, 250-256. 10.1002/ijgo.1287331131885https://www.ncbi.nlm.nih.gov/pubmed/31131885
[53]
Reinhard J., Hayes-Gill B., Yi Q., Hatzmann H., Schiermeier S.: “Signal quality of non-invasive foetal electrocardiogram (ECG) during labour”. Geburtshilfe und Frauenheilkunde, 2009, 69, 703-706. 10.1055/s-0029-1185936http://www.thieme-connect.de/DOI/DOI?10.1055/s-0029-1185936
[54]
Stampalija T., Signaroldi M., Mastroianni C., Rosti E., Signorelli V., Casati D., et al.: “Fetal and maternal heart rate confusion during intra-partum monitoring, comparison of trans-abdominal fetal electrocardiogram and Doppler telemetry”. The Journal of Maternal-Fetal & Neonatal Medicine, 2012, 25, 1517-1520.
[55]
Sänger N., Hayes-Gill B., Schiermeier S., Hatzmann W., Yuan J., Herrmann E., et al.: “Prenatal Foetal Noninvasive ECG instead of Doppler CTG-A Better Alternative”? Geburtshilfe und Frauenheilkunde, 2012, 72, 630. 10.1055/s-0032-13150128276bcda-f080-4138-bae7-081cb049ac7chttp://dx.doi.org/10.1055/s-0032-1315012
[56]
Narayan H.K., Vignola E.F., Fifer W.P., Williams I.A.: “Assessment of cardiac rate and rhythm in fetuses with arrhythmia via maternal abdominal fetal electrocardiography”. AJP reports, 2015, 5, e176. 10.1055/s-0035-155840126495180https://www.ncbi.nlm.nih.gov/pubmed/26495180
[57]
Wacker-Gussmann A., Plankl C., Sewald M., Schneider K.T.M., Oberhoffer R., Lobmaier S.M.: “Fetal cardiac time intervals in healthy pregnancies-an observational study by fetal ECG (Monica Healthcare System)”. Journal of Perinatal Medicine, 2018, 46, 587-592. 10.1515/jpm-2017-000328453441https://www.ncbi.nlm.nih.gov/pubmed/28453441
[58]
Huhn E.A., Müller M.I., Meyer A.H., Manegold-Brauer G., Holzgreve W., Hoesli I., et al.: “Quality predictors of abdominal fetal electrocardiography recording in antenatal ambulatory and bedside settings”. Fetal Diagnosis & Therapy, 2017, 41, 283-292. 10.1159/00044894627811482https://www.ncbi.nlm.nih.gov/pubmed/27811482
[59]
Hayes- Gill B.R., Martin T.R., Liu C., Cohen W.R.: “Relative accuracy of computerized intrapartum fetal heart rate pattern recognition by ultrasound and abdominal ECG detection”. Acta Obstetricia et Gynecologica Scandinavica, 2020. 10.1111/aogs.1396532726457https://www.ncbi.nlm.nih.gov/pubmed/32726457
[60]
Zhivolupova Y.A.: “Analysis of the fetal heart rate variability by means of the abdominal electrocardiogram monitoring system”. 2018 third international conference on human factors in complex technical systems and environments (ERGO) s and environments (ERGO), 2018, IEEE.
[61]
Macones G.: “Intrapartum fetal heart rate monitoring, nomenclature, interpretation, and general management principles”. Obstetrics & Gynecology, 2009, 114, 192-202. 10.1097/AOG.0b013e3181aef10619546798https://www.ncbi.nlm.nih.gov/pubmed/19546798
[62]
Roham M., Saldivar E., Raghavan S., Mehregany M., Shah M.: “Wireless fetal monitoring system”. Google Patents, 2017.
[63]
Gaster R.S.: “Wireless pregnancy monitor”. Google Patents, 2019.
[64]
Lahiji R.R., Roham M.: “Integrated wearable device for detection of fetal heart rate and material uterine contractions with wireless communication capability”. Google Patents, 2019.
[65]
Mugyenyi G.R., Atukunda E.C., Ngonzi J., Boatin A., Wylie B.J., Haberer J.E.: “Functionality and acceptability of a wireless fetal heart rate monitoring device in term pregnant women in rural southwestern Uganda”. BMC Pregnancy & Childbirth, 2017, 17, 178. 10.1186/s12884-017-1361-128595604https://www.ncbi.nlm.nih.gov/pubmed/28595604
[66]
Ginting C.N., Lister I.N.E., Silaen M., Girsang E., Laila Y., Turnip M., et al.: “Fetal heart detection based wide area network technology with wireless sensor transmission”. Journal of Physics, Conference Series, 2019, 1230 012037.
[67]
Schwartz N., Mhajna M., Jakobs M., Aviraham K.B., Reches A., Eswaran H., et al.: “Towards a solution for remote pregnancy monitoring, a novel non-invasive method for uterine activity monitoring”. American Journal of Obstetrics & Gynecology, 2020, 222, S241.
[68]
Kahankova R., Martinek R., Jaros R., Behbehani K., Matonia A., Jezewski M., et al.: “A review of signal processing techniques for non-invasive fetal electrocardiography”. IEEE Reviews in Biomedical Engineering, 2019. 10.1109/RBME.2020.296991532011262https://www.ncbi.nlm.nih.gov/pubmed/32011262
Share
Back to top